Creating a sustainable future
Call us: 01303 248648

Heat Pumps In CT21, Hythe

Site:-   Heat Pump Installation in CT21, Hythe, Nr. Folkestone, Kent.

Dwelling Description:- 279m2 – 5 bed detached property built 2011.

System Design:- Air source heat pump (ASHP), 14kW Mitsubishi Ecodan monobloc with a Kingspan 250litre heat pump cylinder. System was fitted with Stelrad radiators and was sized to a delta t of 20⁰C. Heat loss calculations showed a power requirement of 13.3kW to the property.

Job Ref:- 54

Summary – Customer happy with the running of unit in both performance and economically.

 

Heat Pump Installation In Seabrook CT21

Site:-   Heat Pump Installation in CT21, Seabrook, Nr. Folkestone, Kent.

Dwelling Description:- 152m2 – 3 bed detached property built 2012.

System Design:- Air source heat pump (ASHP), 12kW Vaillant geoTHERM monobloc with a Powerflow 250litre heat pump/solar cylinder. System was fitted with Stelrad radiators and was sized to a delta t of 20⁰C. Heat loss calculations showed a power requirement of 5.98kW to the property.

Job Ref:- 11041

Summary:– Contractor happy with the professionalism of the Reina Group and the quality of their aftercare.

Price your heat pump Book your heat pump service Enquiry